普洱附近想过夜电话联系

Welcome to Yongsheng Machinery. We provide you with mixing machine, feeding machine, automatic mixing line, PET film cleaning line and PE film cleaning line  Scan, the content is more wonderful

National service hotline

thirteen billion seven hundred and seventy-three million two hundred and twenty-one thousand one hundred and sixty-eight
 Immortal machinery
 Immortal machinery

Why doesn't the automatic feeding machine suck?

Release date: September 26, 2020

      Automatic feeding machine Long term use, there will always be some small problems, at this time as equipment management personnel, how to do, such as manufacturers repair delay production. As the saying goes, it's better to ask for others than to ask for yourself. Some simple problems can be solved by ourselves. The most common problem of the automatic feeding machine is that when the pneumatic pump is used as a vacuum source, the material may not be sucked up. There are many reasons for this situation. The following aspects are mainly used for inspection.
1. You can first check the control system if there is a problem, such as the parameters of the automatic feeding machine, suction, discharging time is accurate, if there is a problem here, the suction machine may not be normal suction, should be changed in time.
2. Check the pneumatic pump of the equipment to see if the interface of the compressed air pipeline is matched. In most cases, the air source pressure of the pneumatic pump is between 6 and 7 MPa. If the pipeline connection is normal, you should check the pneumatic pump of the air source.
3. The suction machine can not normally suction, it may also be due to the disassembly and movement of the machine, air leakage in the upper cover and cylinder clamp, which leads to the normal suction operation.
 Automatic feeding machine
4. Replace the upper cover of the feeding machine, take out the filter plate, and then investigate whether there are too many dust impurities on the filter element. Maybe some dust has formed solid clots. In this case, the material suction machine will suck materials under abnormal pressure. If this problem occurs, just use an air gun to clean it.
5. Yes Automatic feeding machine Check whether there is air leakage on the upper part of the suction pipe. Other points to pay attention to is whether there are sealing rings on all clamps, and the sealing rings are not aging or leaking. If the cause of the problem is not found in the above section, the maintenance personnel can still find the reason for the problem.